Ventrex designs and manufactures oxygen and toxic gas sensors for medical and industrial gas detection. The Ventrex sensors are direct replacements available to OEMs for monitoring gases such as oxygen, carbon monoxide and hydrogen sulfide. Ventrex offers off the shelf sensors, private labeling, and sensors for custom applications.

16333 Bay Vista Drive
Clearwater, Florida 33760
Phone 727 531 9642 - Fax 727 535 3654 - Email: info@sensidyne.com


Contact Us
Home
Products

Medical Sensors

Industrial Sensors

Customer
Support

Contact Information

Inquiry Form

Download
Specifications

Authorization to Download Specifications


MEDICAL OXYGEN SENSORS 

Click image to view enlargement

Respiratory

Anesthesia
Suitable for use with Nitrous Oxide

V01V01Respiratory Sensor
Directly compatible with: 
Bertucci
Bio-Med Devices
Bio-Tek
Catalyst (MSA) [478841]
Catalyst (MSA) [485955]
Diversified Diagnostics
Elmed
Emerson
Fraser Hartake [66-00453]
Hamilton [HM-01]
Harris Lake [66-00453]
Healthdyne
Heyer
Inmed
Maxtec [MAX-19]
Medigas
Megamed [M2]
Novacare
Oxequip (allied)
Oxitron [3250]
Patient Tech
Schoch
Sensor Tech (BPR Medical)
[ST-01]
Sun Medical
Teledyne [A-37016T1]
Teledyne [A-38070 T2]
Toptronics
Vickers
V03AV03a.Anesthesia Sensor
Directly compatible with:
Teledyne T7
Catalyst (MSA) [804674]
Maxtec [MAX-17]
Newport [OM 100/OM 105]
Sechrist 850 [4370]
Sensor Tech (BPR Medical) [ST-03]
Teledyne [A-51327 T7]
V02V02.Respiratory Sensor
Directly compatible with:
Catalyst (MSA) [475895]
Catalyst (MSA) [655262]
Maxtec [MAX-18]
Megamed [M1]
Sensor Tech (BPR Medical) [ST-02]
Teledyne [C1]
V11AV11a.Anesthesia Sensor
Directly compatible with:
Alpha Med
BCI
Biotest C 102-1 [720030]
Biotest A 103-1 [720050]
Bird Products Corp [66030]
Catalyst (MSA) [406931]
Damoca
F Stephan GMbH
Hudson RCI [5567]
Lifecare (Resp) PLV-102 [37-079]
Maxtec [MAX-13]
Oxitron [3310]
Puritan Bennett [4-020933-00]
Sensor Tech (BPR Medical) [ST-11}
Taema [YR010100]
Teledyne [C-43690 R17]
Vascular Technology [100580]
V26V26.Respiratory Sensor
Directly compatible with:

Catalyst (MSA) [806572]
V12AV12a.Anesthesia Sensor
Directly compatible with:
Air Shields (Hill-Rom)
Aladdin
Biotest C 102 [720020]
Biotest A 103 [720040]
Catalyst (MSA) [472062]
Catalyst (MSA) [701644]
Criticare Systems
Datascope
Hamilton [HM-12]
Hudson RCI [5566]
Infrasonics [60116]
Maxtec [MAX-12]
Maxtec [MAX-16]
Narco Med
PPG [504055-001]
Puritan Bennett [4-042214-00]
Sensor Tech (BPR Medical) [ST-12]
Siemans Servo [9004975]
Spacelabs [90514]
Teledyne [C-44611 R22]
Teledyne [C-61340 R24]
V250V250.Respiratory Sensor
Directly compatible with:

Maxtec [MAX-250]
V14AV14a.Anesthesia Sensor
Directly compatible with:
Biotest S 101 [720010]
Biotest I 8000 104 [720060]
Biotest D 201 [720100]
Catalyst (MSA) [655263]
Catalyst (MSA) [655264]
Drager [6803290]
Drager 8000 [6850645]
Hewlett Packard [15201A]
Maxtec [MAX-1]
Maxtec [MAX-11]
Ohmeda [0237-2034-700]
Oxitron [3710]
Paragon Service [PS-1000]
Paragon Service [PS-2000]
Sensor Tech (BPR Medical) [ST-14]
Teledyne [C-41131 R15]
Teledyne [C-61339 R23]
Vascular Technology [101272]
Vascular Technology [101372]
  V20AV20aAnesthesia Sensor
Directly compatible with:
Maxtec [MAX-10]
Ohmeda [6050-0004-110]
  V25AV25aAnesthesia Sensor
Directly compatible with:
Maxtec [MAX-250ESF/250E]
 

Common Properties of Ventrex Medical Sensors

  • Linearity:
±1% of full scale when calibrated @ 100% 02
  • Operating Principal:
Galvanic Fuel Cell
  • Primary Sensitivity:
Partial Pressure 02
  • Operating Range:
0 - 100% 02
  • Operating Temperature:
0° C - 40° C
  •  Humidity Range:
0 - 100% Non Condensing
  •  Effect of Relative Humidity:
-0.03% relative 02, per % of Relative Humidity @ 25° C
  • Response Time:
per ISO/DIS 7767
  • Specifications at:
STP

Contact Ventrex to discuss custom applications as well as private labeling.